Double-Door Sealed
Transfer System
Operating Principle

  1. Operations start and finish with a sealed cell enclosure and with a sealed canister. Present the sealed canister to the sealed cell flange.
  2. Orient the canister locking bayonets with the openings on the cell flange. Rotate the canister clockwise 60°. During this rotation the canister will lock and seal to the cell flange, and the canister cover will unlock from the canister and lock and seal to the cell port.

  3. Open the hinged double door
  4. Transfer material to or from the canister, and close the double door.

  5. Rotate the canister counter-clockwise 60°. During this rotation the canister cover will unlock from the cell port and lock and seal to the canister, and the canister will unlock from the cell flange.
  6. Disengage the canister from the cell flange.

Double-Door Transfer Systems | Nuclear Products